<LOGO>
FM Transmitter Measurement Report
Created: 2025-07-25 00-04-40
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
94.70 MHz 4/5, 50 dBuV SANDELS
Pilot RDS Phase Difference
6.0 kHz 4.9 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
17 kHz 67 kHz 4347 0,0230
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
3,9 dBr 5,41 dBr 6,4 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"SANDELS " 61F1 9 (Varied) 1 0 1 13 --:--
RT
-
AF EON
92.0, 94.7, 106.4, 107.5 MHz -
FM Scope Max at: 67 kHz MIN: 17 kHz % above 76 kHz: 0,0230 Acquired: 2025/07/25 0.03.37 Total samples: 4347 Equivalent time: 0:03:37 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 50 100 150 200
FM Scope MAX: 6,4 dBr MIN: 3,9 dBr AVE: 5,41 dBr % above 12,2 dBr: 0,0 Last value: 4,8 dBr (2025/07/25 0.03.36) 23.50 23.52 23.54 23.56 23.58 00.00 00.02 0 2 4 6 Pm [dBr]